How to replace?

  • Step 1: Turn off power and drain the boiler.
  • Step 2: Remove the old element by unscrewing the flange.
  • Step 3: Install the new G199A element and secure with the flange.
  • Step 4: Reconnect power and refill the boiler.

Estimate time?

Approximately 30-60 minutes.